Barton 224 dp unit
The Barton Model 224 Differential Pressure Unit (DPU) is a mechanical device that monitors the parallel differential stress of a gas or liquid passing through a process system or the quantity of liquid stored in a process tank. In the factory-stream measurement process scheme, the DPU is linked to a main unit (e.g., venturi, orifice screen, or flow tube). For liquid concentration readings, the DPU can be linked in a multitude of respects to assess the range of stress induced by fluid density differences in the unit ship.
The Barton Model 224 DPU is accessible in separate stress scores to evaluate particular distances between 0-30 inches of water column and 0-1000 psi, with secure work stress (SWP) outcomes of 500 to 10,000 psi (224 Non-C restricted to 500 to 3,000 psi SWP). Table 1-1, point 4. The 224C Bellows Unit Assembly (BUA) is manufactured in three bellow sizes: 1-5/8 inch, 5/8

Barton Turbine Meter Preamplifier Model 818A and 818EU
CategoryBarton, Barton switches and indicators
TagsBARTON
The ITT Barton Turbine Meter Preamplifier Model 818A converts a low-level signal from the turbine meter pickup coils to square wave signals which are suitable for transmission. Transmissions Up to 3 miles (5 km) for current output and 100 ft (30 m) for voltage output are no problem for the Barton 818A Preamplifier. The output is field selectable – for compatibility with various readout devices. Hazardous location explosion-proof condulet connects to the turbine meter coil boss.
If you need a different model other than those listed, please contact us at contact@ittcontrols.com.
818A l 818
BARTON

Barton 581A Differential Pressure Switch
The Barton Instruments Model 450C indicates low DP in high static pressure applications. Its 4-1/2″ dial provides excellent readability with economy of space. The M450C is a commercial version of the M316C, used by the U.S. Navy for shipboard measurement of DP, flow, and Liquid level. A rugged 4-1/2 inch (114 mm) indicator that offers economy of space and readability. Available with top/bottom or rears ports.ITT Barton M450C features:Aluminum (NEMA 4) or 316SST (NEMA 4X) and weather-proof dial 4-1/2 inch, 270° arc caseactuated by the 224C DPU Indicating Mechanism.
The indicating pointer traverses a 270° arc, providing excellent readability. It is driven by a precision, jeweled rotary movement that employs a thermally stable Ni-Span-C hair spring. The movement has a micrometer screw for range adjustments. Zero and range adjustments can be made without removing the scaleplate or pointer. Linearity adjustments are easily accessible after removal of the scaleplate.
If you need a

Barton Inventory Mngt Products and Systems
CategoryBarton, Barton switches and indicators
TagsBARTON
CryoScan® 60 Remote Tank Telemetry System
The Barton CryoScan® 60 (CS60) Remote Tank Telemetry System is an ideal solution for automating tank inventory management. The ability to remotely monitor storage tank levels helps eliminate product shortage and minimizes the need for “extra” product deliveries. The CS60 provides up-to-the minute tank level measurement using pressure and level sensors or inputs from 4-20 mA transmitters. Up to four sensors can be added to each CS60 unit for added value. Best of all, CS60 users retrieve their tank level data directly from their computer, without having to download files from a website or third-party data host. Built-in alarms alert the operator when a parameter drops to a user-specified setpoint. An operator can also run a status report “on demand” for instantaneous data monitoring.
Quick and easy installation, wall-mount or pole-mount
AC and solar

Barton 288 dp indicating switch
CategoryBarton, Barton switches and indicators
TagsBARTON
Barton 288 Series indicators offer precise, clear and consistent results. As the systems are 100% mechanical, this range of tools are fast and simple to assemble and has become essential to a broad range of applications from fluid tier indicator, estimation of liquefied substances such as LOX, CO2, ammonia, nitrogen, oxygen, oxygen and argon; rocket engine / missile inspection; ventilation and water conditioning devices. These non-powered devices are perfect for distant location apps and critical backup apps. Two rotor feeder roller / actuator frame units, one for each button, react to torque tube spin by entering and locking the buttons as they drive on and off the cam. The DP rates at which the buttons are actuated can be adjusted on the scale panel with elevated and small door button modifications. Standard models may have one or two alarm buttons.If you need a different model other than those listed,

Barton Model 251 and 251C
CategoryBarton, Barton switches and indicators
TagsBARTON
The ITT Barton Model 251 and s51C differential pressure indicating switch used to energize alarm or control circuits at preset values of differential pressure, amount of flow or liquid level. This unit has been tested and succesfully passed all requirements of MIL-S-901C, Grade A and MIL-STD-167 Vibration. If you need a different model other than those listed, please contact us at contact@ittcontrols.com. 251 l 251CBARTON

Barton 291B dp indicating switch
CategoryBarton, Barton switches and indicators
TagsBARTON
In a broad range of secure operating and differential stress ranges, BARTON DP switches are accessible. If you need a different model other than those listed, please contact us at contact@ittcontrols.com. 289A l 291BBARTON

Barton 580A Differential Pressure Switch
When predetermined flow / level limits are exceeded, the 580A Differential Pressure Switch runs single or dual stream systems. Tubing or piping links DPU with the technique or vessel. Changes in differential stress (DP) at the DPU produce a mechanical output that crosses a pointer and click instructions.
The instrument is connected in the technique to the high-pressure and low-pressure sides of a primary device for fluid measurements. The primary tool is normally an orifice, venturi, or stream pipe. For liquid level measurement applications, the instrument is connected to assess changes in differential stress caused by fluid hydrostatic pressures in a tank.
If you need a different model other than those listed, please contact us at contact@ittcontrols.com.
580A
BARTON

Barton 322C dp switch
CategoryBarton, Barton switches and indicators
TagsBARTON
The unit is connected to the primary device’s LP and HP ends (orifice screen, venturi, or flow tube) for fluid applications in the operated system. For the liquid concentration, the DPU is connected to assess the changes in DP produced when the liquid concentration changes. These changes are used to control the button’s operation. The electrical alarm or control unit loop is connected to the button (mounted on the DPU). The motion of the DPU button actuates the shift scheme when the DP approaches a pre-set quantity.
The standard condition for sensors and switches is aluminum die-cast with a distinctive gray epoxy color. Models 316C and 450C have weatherproof cases, while designs 226C, 227C and IT / ITS have a ranked NEMA-4/IP65 case. The Model 232C has a 304 tubular steel frame. Models 290D, 322C, 752, 753, and IT / ITS series pick designs have explosion-proof cases. Optional non-indicating “blind” plug

Barton 318C dp switch
CategoryBarton, Barton switches and indicators
TagsBARTON
The 318, 318A and 318C ITT Barton Model are 4 1/2 “differential pressure switches with MIL-S-901C Shock Grade A and MIL-STD-167 vibration criteria. The scale of ITT Barton Model 318, 318A and 318C can be continually upgraded to evaluate differential flow or fluid or square root flow rate.
The Models 316C DP Indicator and the 318C DP Indicating Switch are designed for apps with differential pressure flow and liquid concentration. In the system cycle, the instrument is connected to the elevated and low pressure sides of the primary instrument with tubing. The M381C energizes a single or dual alarm circuit when the recorded DP reaches predetermined boundaries.
If you need a different model other than those listed, please contact us at contact@ittcontrols.com.
316C l 318C
BARTON

Barton Model 224
CategoryBarton, Barton switches and indicators
TagsBARTON
The Barton Model 224 Differential Pressure Unit (DPU) is a mechanical device that monitors the parallel differential stress of a gas or liquid passing through a process system or the quantity of liquid stored in a process tank. In the factory-stream measurement process scheme, the DPU is linked to a main unit (e.g., venturi, orifice screen, or flow tube). For liquid concentration readings, the DPU can be linked in a multitude of respects to assess the range of stress induced by fluid density differences in the unit ship.
The Barton Model 224 DPU is accessible in separate stress scores to evaluate particular distances between 0-30 inches of water column and 0-1000 psi, with secure work stress (SWP) outcomes of 500 to 10,000 psi (224 Non-C restricted to 500 to 3,000 psi SWP). Table 1-1, point 4. The 224C Bellows Unit Assembly (BUA) is manufactured in three bellow sizes: 1-5/8 inch, 5/8

Barton Electro Hydraulic Motors
CategoryBarton, Barton switches and indicators
TagsBARTON
ITT Controls also provides universal throttle motors made by ITT Barton. ITT Controls also delivers the replacement equipment of these models. This electro-hydraulic motors are out of production but are still available via ITT Controls.
This electro-hydraulic motor is to replace the engines of all current and previous series electrohydraulic gas valves from 3/4 “to 3” screwed and flanged. If you need a different model other than those listed, please contact us at contact@ittcontrols.com. ITT Barton SH-110
ITT Barton SH-120
ITT Barton SH-160
ITT Barton SH-210
ITT Barton SH-220
ITT Barton SH-230
ITT Barton SH-240
ITT Barton SH-260
ITT Barton SH-360
ITT Barton SH-460
ITT Barton SH-480
ITT Barton SH-H110
ITT Barton SH-H120
ITT Barton SH-H160
ITT Barton SH-H210
ITT Barton SH-H220